HI-98196 Hanna Multiparameter Waterproof Meter

£1,480.70

Description

The Hanna HI-98196 measures pH/mV, ORP, Dissolved Oxygen, Atmospheric Pressure and Temperature.

Supplied with a 4m cable.

Dissolved Oxygen, ORP, pH, Temperature.

HI-98196 provides multi-parameter measurement in a compact and rugged IP67 waterproof enclosure. Ideal for demanding application, this meter features our rugged, quick connect multi-function probe with field replaceable sensors. The HI-98196 measures pH/mV, ORP, Dissolved Oxygen, Atmospheric Pressure and Temperature

A backlit, graphic LCD provides easy to read resolution even in low-lit areas. A combination of dedicated and soft keys allows easy, intuitive operation in a choice of languages.

HI-98196 allows users to store up to 45,000 continuous or log-on demand samples with logging intervals from one second to three hours. Logged data can be later transferred to a PC with the HI-920015 micro USB cable and Hanna software.

Comprehensive GLP data includes data from the last five calibrations. The contextual Help Menu can be accessed to obtain on-screen information and assistance about each feature at the touch of a button.

pH specific features

  • Up to three point calibration with five standard buffers and one custom buffer available

Dissolved Oxygen specific features

  • Display units in % saturation of mg/L (ppm)
  • Salinity compensation for concentration
  • Pressure compensation for concentration
  • Built-in barometer with user-selectable units (mmHg, inHg, atm, psi, kPa, mbar)
  • Temperature compensation
  • Automatic polarisation of probe at startup
  • Ready to use HDPE pre-tensioned membrane caps are easy to replace

The HI-7698196 probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.

Key features

  • IP67 rated waterproof, rugged enclosure for meter, IP68 for probe
  • Colour-coded, field replaceable sensors
  • Auto sensor recognition
  • Automatic logging of up to 45,000 samples
  • Store measurement data at the press of a button
  • On-screen context specific help is readily available at the press of a button
  • PC connectivity via opto-isolated micro-USB with Hanna software
  • Up to 360 hours of battery life, powered by (4) 1.5V batteries
  • The HI-7698196 probe features a quick connect DIN connector for a water tight connection

IP68 – Electrode is dust-tight and protected against the effects of continuous immersion in water beyond 1m.

PC Interface – Download test results to a computer programmed with HANNA’s Windows® compatible software (HI-92000), directly from equipment via a USB port or a RS232 cable outlet.

Specification Product Literature
pH/mV Range 0.00 to 14.00 pH/± 600.0 mV
Resolution 0.01 pH/ 0.1 mV
Accuracy ±0.02 pH/ ±0.5 mV
Calibration automatic up to three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP Range ±2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
Dissolved Oxygen Range 0.0 to 500.0%, 0.00 to 50.00 ppm
DO Resolution 0.%; 0.01 ppm (mg/L)
DO Accuracy 0.0 to 300.0%; ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%; ±3% of reading; 0.00 to 30.00 ppm (mg/L); ±1.5% of reading or ±0.10 ppm (mg/L). whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L); ±3% of reading
DO Calibration automatic one or two points at 0.100% or one custom point
Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy ±3mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration automatic at one custom point
Temperature Range -5.00 to 55.00°C
Temperature Resolution 0.01°C
Temperature Accuracy ±0.15°C
Temperature Calibration Automatic at one custom point
Additional Specifications
 Maximum probe immersion Depth – 20 metres
  Temperature compensation automatic from -5 to 55°C
  Logging Memory 45,000 records (continuous logging or log-on demand of all parameters
  Logging Interval one second to three hours
 PC Connectivity via USB (with Hanna PC software)
  Environment 0 to 50°C; RH 100% IP67
  Battery Type/Life 1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight)
  Dimensions/Weight 185 x 93 x 35.2 mm/400g
Ordering information: HI-98196 is supplied with HI-7698196/4 multiparameter probe, HI-7698194-1 pH/ORP sensor, HI-7698194-2 DO sensor, HI-9828-20 quick calibration solution, HI-76981942 Probe maintenance kit, HI-76981943 Calibration beaker, HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom insert.
Download Manual PDF Here.